By Pass Rotameter

Manufacturer And Exporter of Process Equipment And Measuring Instruments

By Pass Rotameter

At high ranges of fluid in pipe lines between 2'" and higher and up to 300 mm NB, use a by-pass rotameter. where rotameter cannot be used on a line. One orifice plate is included, and it is fixed in the pipe between two flanges. There is one additional integrated orifice with two inlet and output ports and one bypass Rotameter available to measure direct flow. We are Gujarat, India's top manufacturer, supplier, and exporter of by-pass rotameters.

The flow metre of the Inference kind is the By-Pass Rotameter. A main line orifice plate is used to generate differential pressure (DP). Branch pipes are placed across the upstream and downstream sides of the orifice plate, and fluid flows through them as a result of the differential pressure. The by-pass line has a second range orifice plate since the flow through it will be proportional to the flow through the main line.

By Pass Rotameter Suitable for high range of fluid in pipe line between 2'" or above upto 300 mm NB. Where on line rotameter cant be used. It consist of one orifice plate to be mountedin the pipe line between two flange. one more integral orifice with two inlet & outlet & one by pass Rotameter is provided to read, direct flow. we are leading manufacturer, supplier & exporter of by pass rotameter in gujarat, India.
Material of wetted part M.S / C.S. / S.S.304 / S.S.316
Orifice range 25 to 10000M'/ HR of water
Accuracy ±2 % full scale reading

Accessories of By Pass Rotameter

• Isolation valve
• High & low flow alarms
• With 4-20mA two wire
  transmitter
• Digital Indicator, Totaliser.

Operating Principle & Standard Features

  •   Differential pressure ‘P’ is created in the main Flow by providing an Orifice plate in the main pipeline.
  •   Because of this ‘P’ a branch of flow moves through By-Pass line provided across the orifice plate from up stream side to down stream side of the Orifice Plate.
  •   Additional Range Orifice plate is provided in the By-Pass line which is designed such that flow through range Orifice plate flows in proportion with the flow through main orifice plate.
  •   Hence by measuring the flow from By Pass line we can estimate the flow from Main Pipe line.

Standard Features

Easy to Maintain
On - Line Installation
Most Economical,Low Cost
Pipe Size - 40 NB to 300 NB
For High Flow - 8M / Hr. To 1500M / Hr.
Two tone powder coated excellent finish
No threads, No leakage, Avoids corrossions
Rangeability - 1:10 2 : 10
Heavy duty design with maximum visibility
Various options for material of construction of wetted parts
Main Line

NB
MM
PRESSURE DROP METERS OF H2O
1.2
2.5
3.8
5
10
1.2
2.5
3.8
5
10
LIQUID M³ / Hr
  AIR NM³ / Hr
40
8
12
14
16
22
 
246
350
425
492
730
50
13
19
22
27
38
 
407
577
713
815
1206
65
19
27
34
38
54
 
594
849
1019
115
1699
80
29
40
52
59
83
 
917
1274
1580
1835
2684
100
59
86
104
120
170
 
1869
2616
3228
3738
5437
125
95
136
163
188
272
 
2888
4078
5097
5777
8496
150
136
192
227
272
385
 
4248
5947
7306
8496
12234
200
227
340
408
476
658
 
7306
10365
12744
14613
21409
250
363
522
635
749
1044
 
11554
16482
20390
23109
33984
300
522
749
930
1066
1498
 
16482
23109
28036
32284
47577